C-Top

Benchtop incubator for up to date,

individual cell cultivation

 

  • DESCRIPTION

    Advantages of Labo C-Top:

    Approved medical device

    Two independent and separate incubation chambers;

    Parameters (gas flow, temperature) can be adjusted individually

    Optimized gassing with premixed gas

    Optimized temperature distribution by double heated chamber from top and bottom;

    Very fast heating up and recovery times

    Reliable humidity system;

    Current value of relative humidity is displayed (% rH)

    Convenient glass control panel

    Space saving

  • FEATURES

    Incubation chambers

    Aluminum milled and eloxated

    In the lower part:

    Slots provide full contact to culture dishes

    Adaption for humidity block

    Gas inlet

    Easy cleaning

    Independent, for use with (per chamber):

    4 x IVF 4-well dishes 66x66 mm

    4 x Petri dishes Ø 60 mm

    10 x Petri dishes Ø 35 mm

    Temperature

    Overall heating from top and bottom

    Very homogeneous temperature distribution

    Humidity

    Humidification by means of humidity block

    Reservoir sufficient for 4 days (when gassing with 20 ml/min)

    Humidity block autoclavable

    Humidity alarm disengageable

     

    Current value of relative humidity is displayed (% rH)

     

    Gassing

    Connection of premixed gas (CO2, O2 < 21 %, N2)

    Separate measuring and regulation of gas flow for each chamber

    Automatic gas purge when closing the chamber

    Recovery times

    Short recovery times for all parameters through microprocessor controlled regulation

    Use of glass panel

    Homogeneous glass cover

    Sensoric buttons integrated in glass

    Image of placements for marking inserted dishes at the glass cover

    Easy operation and menu navigation

    Lit LCD at working place height

    Trouble check system

    Optical and acoustic alarm in case of set point deviation or defective sensor

    Independent over-temperature protection

    Remote alarm

    Options

    PC software LaboDat+ for documentation of incubator’s parameters

    Second gas inlet for use of different gas mixtures for each chamber

    Lockable lids

    Interfaces

    Remote alarm (potential free)

    RS485-interface for data logging with optional available PC software LaboDat+

  • SPECIFICATIONS

    Exterior

    Dimensions 403 x 225 x 155 mm (w x d x h)

    Weight 8.8 kg

    Interior

    Two chambers with 0.5 liters each

    Mixed load possible

    Temperature

    Overall heating from top and bottom of each chamber

    Range 30 °C - 42 °C from 7 °C above

    ambient temperature

    Stability / uniformity ± 0.1 °C / ± 0.3 °C

    Gassing

    Premixed gas

    Gas flow adjustable between 20 ml/min and 30 ml/min

    Flow rate after opening the lid (automatic gas purge):

    250 ml/min for 3 minutes

    Power Supply

    110 – 230 V AC, 50/60 Hz, 100 VA

    Primary pressure for gas 0.8 bar

    Ambient temperature 18 °C - 30 °C

    Classification

    Safety class II

    Class IIa for every usage according to EC-Directive 93/42/EEC

    EN 61010 conform

C16 Incubator

Incubator with an inner volume of 16 liters

  • DESCRIPTION

    Advantages of C60:

    Approved medical device

    Active sterile humidity:

    External water reservoir

     

    Distilled water is vaporized at 120 °C

     

    Minimized risk of contamination

     

    Humidity sensor (rH)

     

    Very fast recovery

     

    CO2 sensor:

    Dual beam infrared sensor

     

    Very precise measurement

     

    Very fast recovery

     

    Long-term stable

     

    Direct heating:

    Independent six-sided direct heating

     

    Homogeneous temperature distribution in incubation chamber

     

    Very fast recovery

     

    Optional:

    O2-control

    Subdivided inner glass door with 4 small doors

    Lockable front door

    Access port

    PC software LaboDat+

  • SPECIFICATIONS

    Exterior Dimensions 510 x 540 x 720 mm (w x d x h)

    Interior Chamber volume 60 l

    Electro-polished stainless steel

    Shelves height adjustable

    Temperature Panel heated interior chamber and door

    Range 27-42 °C starting 5 °C above ambient temperature

    Stability / uniformity ±0.1 °C / ±0.3 °C

    Over-temperature alarm 32-47 °C

    CO2 control Dual beam infrared sensor

    Range 0–10 % CO2

    Stability ±0.1 % CO2

    O2 control < 21 % (optional) Measurement with galvanic sensor

    Connection of N2

    Adjustable range 1–21 % O2

    Humidity Active sterile humidity generated by vaporizing module at 120 °C

    Measuring range 0–98 % rH / range 60–95 % rH

    Supply 230 V AC, 50/60 Hz or 115 V AC, 50/60 Hz, 160 W

    Inlet pressure for gas 0.8 bar

    Ambient temperature 18-30 °C

    Classification

    Safety class I

    Class IIa for all usage according to EC-Directive 93/42/EE

     

    Conform to ENN 61010

  • FEATURES

    Interior

    Electro-polished stainless steel with coved corners

    Shelves and ductwork easily removable for cleaning purposes

    Temperature Panel heated interior chamber and door

    Humidity supply

    Internal water reservoir

    CO₂

    Dual beam infrared sensor

    Measurements independent from temperature and humidity

    Very short recovery times

    For all adjustable parameters through optimized microprocessor control

    Easy Handling

    Menu guided

    Backlit LCD display

    Foil keypad

    Diagnostic system

    Optical and acoustical alarm if set point deviation or sensor defect occurs

    Door monitoring

    Air monitoring

    Hardware self-test

    Remote alarm

    Options

    O₂ control: connection for N₂

    Interfaces

    Remote alarm (potential free)

    RS485-interface for data-logging with optional PC software LaboDat+

     

C60 Incubator

Incubator with an inner volume of 60 liters

  • DESCRIPTION

    Advantages of C60:

    Approved medical device

    Active sterile humidity:

    External water reservoir

     

    Distilled water is vaporized at 120 °C

     

    Minimized risk of contamination

     

    Humidity sensor (rH)

     

    Very fast recovery

     

    CO2 sensor:

    Dual beam infrared sensor

     

    Very precise measurement

     

    Very fast recovery

     

    Long-term stable

     

    Direct heating:

    Independent six-sided direct heating

     

    Homogeneous temperature distribution in incubation chamber

     

    Very fast recovery

     

    Optional:

    O2-control

    Subdivided inner glass door with 4 small doors

    Lockable front door

    Access port

    PC software LaboDat+

  • FEATURES

    Interior

    Electro-polished stainless steel with coved corners

    No tools required for quick assembly and disassembly of interior

    Temperature

    Panel heated chamber and door

    Intelligent temperature control system avoids condensation in inner chamber

    Active sterile Humidity supply

    External water supply container

    CO2 control

    Dual beam infrared sensor

    Measurement independent from temperature and humidity

    Fast recovery

    For all adjustable parameters through optimized microprocessor control

    Easy handling

    Menu guided

    Large, backlit LCD

    Foil keyboard

    Diagnostic system Visual and acoustic alarm if set point deviation or sensor defect occurs

    Door monitoring

    Remote alarm

    Options

    O2 control: connection of N2

    Subdivided inner glass door with 4 small doors

    Lockable front door

    Access port Ø 30 mm

    Interfaces

    Alarm contact (potential free)

    RS485 interface for connection of optional available PC software LaboDat+

     

  • SPECIFICATIONS

    Exterior Dimensions 510 x 540 x 720 mm (w x d x h)

    Interior Chamber volume 60 l

    Electro-polished stainless steel

    Shelves height adjustable

    Temperature Panel heated interior chamber and door

    Range 27-42 °C starting 5 °C above ambient temperature

    Stability / uniformity ±0.1 °C / ±0.3 °C

    Over-temperature alarm 32-47 °C

    CO2 control Dual beam infrared sensor

    Range 0–10 % CO2

    Stability ±0.1 % CO2

    O2 control < 21 % (optional) Measurement with galvanic sensor

    Connection of N2

    Adjustable range 1–21 % O2

    Humidity Active sterile humidity generated by vaporizing module at 120 °C

    Measuring range 0–98 % rH / range 60–95 % rH

    Supply 230 V AC, 50/60 Hz or 115 V AC, 50/60 Hz, 160 W

    Inlet pressure for gas 0.8 bar

    Ambient temperature 18-30 °C

    Classification

    Safety class I

    Class IIa for all usage according to EC-Directive 93/42/EE

     

    Conform to ENN 61010

C200

Incubator with an inner volume of 200 liters

  • DESCRIPTION

    Advantages of C200:

    Approved medical device

    Active sterile humidity:

    External water reservoir

    Disteilled water is vaporized at 120 °C

    Minimized risk of contamination

    Humidity sensor (rH)

    Very fast recovery

    CO2 sensor:

    Dual beam infrared sensor

    Very precise measurement

    Very fast recovery

    Long-term stable

    Direct heating:

    Independent six-sided direct heating

    Homogeneous temperature distribution in incubation chamber

    Very fast recovery

    Optional:

    O2 control

    Subdivided inner glass door with 6 small doors

    Lockable front door

    Access port

    PC software LaboDat+

  • FEATURES

    Interior

    Electro-polished stainless steel with coved corners

    No tools required for quick disassembly and assembly of interior components

    Temperature

    Panel heated chamber and door

    Intelligent temperature control system avoids condensation in inner chamber

    Active sterile Humidity supply

    External water supply container

    CO2 control

    Dual beam infrared sensor

    Measurement independent from temperature and humidity

    Fast recovery

    For all adjustable parameters through optimized microprocessor control

    Easy handling

    Menu guided

    Large, backlit LCD

    Foil keyboard

    Diagnostic system

    Optical and acoustic alarm if set point deviation or sensor defect occurs

    Door monitoring

    Remote alarm

    Options

    O2 control: connection for N2 possible

    Subdivided inner glass door with 6 small doors

    Lockable front door

    Access port Ø 30 mm

    Interfaces

    Remote alarm (potential free)

    RS485 interface for connection of optional available PC software LaboDat+

  • SPECIFICATIONS

    Exterior Dimensions 680 x 690 x 930 mm (w x d x h)

    Interior Chamber volume 200 l

    Electro-polished stainless steel

    Shelves height adjustable

    Temperature Panel heated interior chamber and door

    Range 27-42 °C starting 5 °C above ambient temperature

    Stability / uniformity ±0.1 °C /  0.3 °C

    Over-temperature alarm 32-47 °C

    CO2 control Dual beam infrared sensor

    Range 0–10 % CO2

    Stability ±0.1 % CO2

    O2 control < 21 % (optional) Measurement with galvanic sensor

    Connection of N2

    Adjustable range 1–21 % O2

    Humidity Active sterile humidity generated by vaporizing module operating at 120 °C

    Measuring range 0–98 % rH / adjustable range 60–95 % rH

    Supply 230 V AC, 50/60 Hz or 115 V AC, 50/60 Hz, 200 W

    Inlet pressure 0.8 bar

    Ambient temperature 18-30 °C

    Classification Safety class I

    Class IIa for all usage according to EC-Directive 93/42/EEC

    Conform to EN 61010

     

Cell Trans 2018

Transport incubator

  • DESCRIPTION

    Transport incubator for a secure and mobile preservation of specimen, culture media etc.

  • FEATURES

    Secure transport of cells without electric mains and CO2 connection

    Factory-aligned parameters: 37 °C and 5 % CO2

    Different temperature or CO2 concentration possible (to be advised before order)

    Operation at 12 V car voltage possible

    Use of different heating blocks

    Easy handling and cleaning

    Compact Design

     

    Parameters* during transport without connection to electric mains and CO2 bottle:

     

    Time Temp. CO2

    0 min 37 °C 5 %

    10 min 36.6 °C

    4.9 %

     

    30 min 35.5 °C 4.8 %

    60 min 34.0 °C 4.7 %

    *The measurements relate to an ambient temperature of 23 °C .

  • SPECIFICATIONS

    Power supply

    115 V or 240 V AC, 50/60 Hz

    12 V DC with car voltage via adapter cable

    Dimensions

    Outside: 385 x 245 x 305 mm (l x w x h)

    Inside:    approx. 312 x 167 x 140 mm (l x w x h)

    Weight

    Approx. 4.7 kg

    Temperature

    Available between 32 °C and 39 °C (to be advised before order)

    Accuracy of regulation

    ± 0.3 °C (measured with heating block REF 10264)

    Heating up time

    Approx. 2 h

    CO2 concentration

    5 % (different concentrations possible)

    Heating block inside necessary

    Connection to CO2 supply with pre-pressure of 0.8 bar necessary

    CO2 accuracy ± 0.3 % CO2 (when supplied with CO2 with pre-pressure of 0.8 bar ± 0.05 bar)

     

Cell Trans +

CO2 transport incubator for a secure and mobile preservation of specimen, culture media etc.

 

  • DESCRIPTION

    Advantages of CellTrans+:

    Can also be used as back up in case of incubator or power outage

    Temperature adjustable between 30 °C and 42 °C

    CO2 adjustable between 0 % and 10 %

    Reliable humidity system

    Easy handling and cleaning

    Compact design

    Insert for 16 Falcon tubes of 5ml and 13ml each

     

     

    Duration with completely charged accumulator:

    At 2 °C ambient temperature approx. 4 h

    At 10 °C ambient temperature approx. 6 h

    At 23 °C ambient temperature approx. 10 h

  • FEATURES

    Interior chamber

    Anodized aluminum

    Insert: stainless steel

    Temperature

    Over-all heating of lateral surface, bottom and lid of incubation chamber

    Homogeneous temperature distribution

    Humidity

    Via humidifying disc Ø 50 mm

     

    CO2

    Dual beam infrared sensor

    Measurements independent of temperature and humidity

    Recovery times

    Short recovery times for all adjustable parameters through microprocessor controlled regulation

    Easy navigation

    Menue guided

    Backlid LCD

    Interfaces

    USB interace for data evaluation via PC Software DataVISUAL ’19 (in scope of supply) (Compatible up to Windows 10)

  • SPECIFICATIONS

    Power supply

    100 V – 240 V, 60 W

    12 V car cable

    Dimensions Exterior:

    386 x 251 x 370 mm (l x w x h in mm)

    Interior:

    ø 160 mm, Height 130 mm, volume approx. 1.7 l

    Empty weight approx. 10 kgs.

    Temperature control

    Control range 30 °C – 42 °C at 3 °C above room temperature

    Temperature homogeneity ± 0.2 °C

    Temperature stability ± 0.1 °C

    CO2 regulation

    Control range 0 – 10 % CO2

    Control accuracy 0.3 % CO2

    CO2 pressure tank

    Capacity 0.4 l

    Pressure 8 bar

    Classification

    Safety class I

    Conform to EN 61010

Thermo Cell

Incubator Controller with Available Case

  • DESCRIPTION

    Transport Incubator for Safe & Versatile Use

     

  • FEATURES

    •Factory-aligned temperature at 37 °C

    •Different temperature possible (to be advised before order)

    •Continuous operation with power supply, car voltage or integrated accumulator during transport

    •Operation with batteries up to 5 hours (at 22 °C ambient temperature)

    •For use with 8 x 13 ml Falcon tubes (REF 13881) or 2 x 13 ml and 8 x 5 ml Falcon tubes (REF 16518)

    •Compact design

     

  • SPECIFICATIONS

    Dimensions 111 x 111 x 215 mm (w x d x h)

    Weight    2.4 kg

    Power supply 100 - 240 V AC, 50/60 Hz

    Temperature Between 32 °C and 42 °C available

    (to be advised before order)

    Accuracy of regulation ± 0.3 °C

    Heating up time 22 °C to 37 °C approx. 1 h*

    Operation time With power supply or 12 V car voltage continuously

    With accumulator approx. 5 h*

    Charging time of accumulator Approx. 3 h*

    Heating block For use with 8 x 13 ml Falcon tubes (REF 13881) or 2 x 13 ml and 8 x 5 ml Falcon tubes (REF 16518)

    *at 22 °C ambient temperature

InControl

Measuring Device, InControl 1050, InControl

  • DESCRIPTION

    Independent measuring device for control and evaluation of CO2, temperature and O2

  • FEATURES

    Accurate measuring of CO2, temperature and optional O2

    Single or continuous measurement in arbitrary intervals

    Measurement and documentation of multiple incubators

    Documentation of measurements with date, time and incubator number

    Easy menu navigation

    Data-Download via USB; PC software DataVISUAL`09 incl.

    Continuous operation by Li-Ion battery or mains adapter possible

  • SPECIFICATIONS

    Case Plastic (ABS)

    CO2 measurement Dual beam infrared sensor

    Range: 0 - 10 % CO2

    Display definition: 0.1 % CO2

    Accuracy:

    0 - 6 % CO2 ± 0.2 % CO2

    6 % - 10 % CO2 ± 0.3 % CO2

    Sample volume per measurement (2 min.): approx. 0.8 l

    Temperature measurement Platinum temperature sensor PT1000

    Range: 0 - 100 °C

    Display definition: 0.1 °C

    Accuracy:

    20 °C - 50 °C ± 0.2 °C

    50 °C - 100 °C ± 0.3 °C

    O2 measurement Galvanic sensor

    Range: 0 - 100 % O2

    Display definition: 0.1 % O2

    O2 sensor not included

    Data logger

     

    Recording of measurement logging in arbitrary intervals

    Output of measurements via:

    backlit LCD

    PC software Data Visual’09 (via USB data cable)

    Interval for data logging: 15 - 120 min., adjustable in steps of 5 min.

    Storage of max. 1008 measurements with date and time

    Power supply Rechargeable Li-Ion battery

    Power supply 100 – 240 V AC, 5 V DC 1.5 A

    Operation time Use of rechargeable battery approx. 4 h

    Time to recharge battery approx. 4 h

Hot Plates A3, A4

Large hotplates for laboratory and scientific use

  • DESCRIPTION A3 HOT PLATE

    Advantages:

    Temperature control between 27 °C and 45 °C

    Homogeneous temperature distribution

    Planar surface for optimal heat transfer to heating blocks, culture dishes and slides

    Easy to clean glass surface

    Short heating up time

    Extremely flat with bigger work surface

    Space saving due to separate control unit

  • SPECIFICATIONS A3 HOT PLATE

    Dimensions 420 x 300 x 23 mm (w x d x h)

    Weight    5.5 kg

    Temperature Adjustable between 27 °C and 45 °C

    Heating up time < 15 min.

    Power supply 100 – 240 V AC, 50/60 Hz, 140 W

    Classification Protection class IPX1 (Hot Plate)

    Protection class IPX0 (Controller)

    Safety class I

    Cable length

    Between Controller and Hot Plate 1.5 m

  • DESCRIPTION A4 HOT PLATE

    Advantages:Robust and planar glass surfaceHomogeneous temperature distributionOLED display for intuitive and easy-to-use user menuFunctional buttons with haptic feedback via vibration (disengageable)Extremely flat and space savingCleaning and disinfection with all common detergents

  • SPECIFICATIONS A4 HOT PLATE

    Dimensions 300 x 210 x 15 mm (w x d x h)

    Usable surface area 255 x 140 mm

    Weight    1050 g (w/o mains adapter)

    Temperature stability ±0.2 °C

    Temperature homogeneity ±0.3 °C

    Temperature Adjustable between 27-45 °C (2 °C above ambient temperature)

    Heating up time Approx. 10 min.

    Power supply 100 – 240 V AC, 60 W

    Cable length Hotplate to mains adapter 1.8 m, mains adapter to plug 1.8 m

215-672-4838

info@nextgenlifelabs.com

Follow Us

<

NextGen LifeLabs provides specialized, cutting-edge equipment, services, and support for the modern A.R.T. laboratory. The ONLY Company that customizes equipment to meet your needs.

Follow Us

CONTACT US

384 Nina Way

Warminster, PA 18974

Office: 215-672-4838

Email: info@nextgenlifelabs.com

Fax: 215-672-4904

CONTACT US

Submitting Form...

The server encountered an error.

Form received.

© 2020 Copyright NextGen Life Labs, All Rights Reserved.